Re: Shop Benches, Bombarder and other.

Posted By: George Vidas
Date: Sunday, 22 March 2015, at 6:03 p.m.

In Response To: Re: Shop Benches, Bombarder and other. (Mike Muldowney)


> The rough pump has only on/off, but
> the diffusion pump has a dial....for this
> initial 'pump down' should I just keep it on
> low?

That dial almost certainly controls the temperature of the heater.

I have an old document somewhere on how to set up a diffusion pump, maybe produced by Transco or Voltarc back in the day. I could scan it if anyone wants.

The gist that I recall is: start with the heater low and the backing pump on; let the oil and heater get up to temperature (an hour or so); and then gradually turn up the heater (half a notch per half hour, lets say) until the top ring is just barely warm, or, as Sean said, there is no visible vapor activity.

On the bombarding table, I drilled holes in 2x4's to slide 4' sticks of 15mm clear thru. In retrospect, I should have done notches or larger holes -- the holes are snug enough that I never pull the glass out to clean the table properly.