Re: More Info

Posted By: SVP Neon Equipment
Date: Thursday, 18 September 2008, at 4:46 p.m.

In Response To: Re: More Info (Tom H.)


> Mark , thanks so much for sharing your
> expertise on this job . I wish I would have
> had an opinion in the original design of
> this sign , but I'm just being hired to
> remake existing units . It's applications
> like this , that if not done correctly ,
> give our industry and our product a bad name
> . Thanks again for your input .

Ah, I didn't know you were replacing existing units. In that case, it would be in everyone's best interest to try and find out all you can about the original units, especially what the fill pressure was. If they were filled to "standard" pressure and you over pressure them in an effort to make them last longer, it may overload the transformer. If that happens, all the transformers will have to be replaced with larger ones. Or, if they were originally over pressured it would be good to know by how much so you can duplicate the pressure so the transformer will be loaded correctly (assuming it was to begin with). Yes, I agree - not a good situation to be in for you.


SVP Neon Equipment