Re: Fire ball
Posted By: Sean S In Response To: Re: Fire ball (Dana)
Date: Thursday, 7 December 2006, at 2:22 p.m.
That happened to me in front of the gas guys when I set up my second shop. I turned the gas on and then hestiated and turned on the air. This was with the ribbon and I never activated the economiser. I (now)always turn the air on before the gas and start the ribbon before even opening the gas.
> Test or replace the gas pressure regulator.
> You may have 2 regulators in the line or one
> 2-stage regulator.> Check the air supply pressure when turned
> on, then when hot. Check air filter and
> relief valve operation.> One of your pressures is wildly changing. I
> would think the gas would be the most likely
> given the tank filling relation when
> pressure is at its highest.
|
Neon Bender's BBS! is maintained by Kenny with WebBBS 5.12.