Re: EGL electrode issues
Posted By: SVP Neon Equipment In Response To: Re: EGL electrode issues (Don Miner)
Date: Saturday, 21 October 2006, at 2:11 p.m.
> From my past experience when using tubelated
> electrodes, I let the trodes get cold before
> I dump the mercury. When dumping mercury on
> hot trodes, I had severe staining. As for
> the flicker problem, a slight flicker I have
> noticed does not present any damaging
> problems. Perhaps Sean S. from EGL will be
> able to explain further. Good Luck, DonDon,
With all due respect, if good materials are used and the tube is well processed (proper glass & electrode temperature, quickly evacuated to less than 1 micron, etc.) the mercury is pure and everything else is how it should be, you should be able to dump the mercury in a hot tube (150°C / 300°F) on hot electrodes and not get any staining. You will get immediate vaporization of the mercury, which will cloud the glass of the electrode. But no staining due to chemical reactivity with the mercury.
Mark
|