Re: calibrating procedure
Posted By: Joe Sniezek In Response To: Re: calibrating procedure (SVP Neon Equipment)
Date: Tuesday, 29 August 2006, at 6:12 p.m.
So you'd need a milliammeter that can handle 15,000 volts, right? Where can a person buy something like that?
> You can get a map measuring device at a
> drafting supply store or most sign supply
> distributors. However, keep in mind that the
> transformer footage chart is only meant as a
> guideline. Actual transformer load should be
> checked at the job site (or duplicate the
> job site voltage with a Variac) with either
> a milliammeter or high voltage probe. The
> general consensus is that the high voltage
> probe is a better choice. However, the mA
> meter is by far better than footage chart
> guess work.> Mark Snyder
> SVP Neon Equipment
> Ph. 803-783-1165
> www.svpneon.com Manufacturers of Quality
> Neon Processing Equipment
|