Re: Gas Ballast Adjustment
Posted By: SVP Neon Equipment In Response To: Re: Gas Ballast Adjustment (Dana)
Date: Friday, 18 August 2006, at 11:34 a.m.
> Thanks, Mark. I thought I heard somewhere
> along the way that a 'setting' was needed to
> make sure water or air could purge if
> present or excessive. I see what you mean.
> And during my setup and testing, I can see
> air entrained into the oil which I will
> allow a small opening for a bit, then close.If air bubbles / "foaming" in the oil continues you may have a leak. Obviously at the beginning of a pumping cycle you will pull a large amount of air through the oil. But after a few hours of hard vacuum there shouldn't be much air in the oil if everything is leak-free.
|