Re: calibrating procedure
Posted By: SVP Neon Equipment In Response To: calibrating procedure (sparky)
Date: Thursday, 8 June 2006, at 8:06 p.m.
> just a quick one guys, how do you all work
> out transformer sizes i.e measuring tube
> lengths i ask because i am using a tape
> meausuer which i know isnt acurate. i have
> tried to get a map wheel but cant . any body
> know where i can get one?You can get a map measuring device at a drafting supply store or most sign supply distributors. However, keep in mind that the transformer footage chart is only meant as a guideline. Actual transformer load should be checked at the job site (or duplicate the job site voltage with a Variac) with either a milliammeter or high voltage probe. The general consensus is that the high voltage probe is a better choice. However, the mA meter is by far better than footage chart guess work.
Mark Snyder
SVP Neon Equipment
Ph. 803-783-1165
www.svpneon.com
Manufacturers of Quality Neon Processing Equipment
|
Neon Bender's BBS! is maintained by Kenny with WebBBS 5.12.