The Neon Bender's BBS!

[ View Thread ] [ Post Response ] [ Return to Index ] [ Read Prev Msg ] [ Read Next Msg ]

Re: hyde 24" ribbon burner

Posted By: Mark@SVP
Date: Wednesday, 22 June 2005, at 5:32 p.m.

In Response To: Re: hyde 24" ribbon burner (Sean S)


> Loose the compressor and get the blower
> going and put a relief valve on there and
> your problems should be fixed.

Agreed. Low pressure (2-3 psi) and high volume is what you need, not the high pressure and low volume that you are getting from that compressor.

Keep the air line from the blower as wide and as short as possible.

Good luck!

Mark


Messages In This Thread

[ View Thread ] [ Post Response ] [ Return to Index ] [ Read Prev Msg ] [ Read Next Msg ]

Neon Bender's BBS! is maintained by Kenny with WebBBS 5.12.

This page Copyright © 1996-2005 Krypton Neon