The Neon Bender's BBS!

[ View Thread ] [ Post Response ] [ Return to Index ] [ Read Prev Msg ] [ Read Next Msg ]

Re: hyde 24" ribbon burner

Posted By: Mark@SVP
Date: Wednesday, 22 June 2005, at 8:22 a.m.

In Response To: hyde 24" ribbon burner (sparky)


> I HAVE A REAL BAD PROBLEM WITH MY 12 MONTH
> OLD 24"RIBBON BURNER . THE PROBLEM IS
> WHAT I WOULD CALL HOT SPOTS. AT EITHER END
> TO ABOUT 5" IN THE GLASS WILL GET
> HOTTER AND SO BEND MORE THAN THE MIDDLE
> SECTION (UP TO 14" ON A LONG CURVE ). I
> AM IN THE U.K AND SO FAR HAVE NOT BEEN ABLE
> TO FIND A SOLOUTION TO THIS PROBLEM . HERE
> THEY WOULD RATHER SELL YOU A NEW ONE (
> PROBABLY WITH THE SAME ISSUES??????) THAN
> GIVE ME A QUICK FIX. SO I APPEAL TO YOU ALL
> OVERSEAS HOPING THAT MOST OF YOU HAVE HYDE
> BURNERS AND HAVE SEEN (AND RECTIFIED THIS
> PROBLEM ) CHEERS

> PS GREAT SITE WISH I WAS OVER THERE
> MARTIN , MANCHESTER , U.K.

Can you give us some more info on your blower set up and air lines? Size of blower, CFM (cubic feet per minute), pressure, size (diameter) and length of air line from the blower, etc.

For a 24" ribbon you need a lot of air volume but not a lot of pressure. If you try to boost the pressure to obtain more volume you can get the undesired affect that you are describing.

Mark