Re: hyde 24" ribbon burner

Posted By: Sean S
Date: Wednesday, 22 June 2005, at 8:20 a.m.

In Response To: hyde 24" ribbon burner (sparky)


What size air and gas line do you have? how are you regulating air and gas? What type of blower do you have. Are you running an artificial ribbon on natural? What size is your main air supply and gas run and how long with how many turns. What is the pressure in your air line. Do you have the lines hooked up properly (air to the large and gas to the small port on the economiser)

> I HAVE A REAL BAD PROBLEM WITH MY 12 MONTH
> OLD 24"RIBBON BURNER . THE PROBLEM IS
> WHAT I WOULD CALL HOT SPOTS. AT EITHER END
> TO ABOUT 5" IN THE GLASS WILL GET
> HOTTER AND SO BEND MORE THAN THE MIDDLE
> SECTION (UP TO 14" ON A LONG CURVE ). I
> AM IN THE U.K AND SO FAR HAVE NOT BEEN ABLE
> TO FIND A SOLOUTION TO THIS PROBLEM . HERE
> THEY WOULD RATHER SELL YOU A NEW ONE (
> PROBABLY WITH THE SAME ISSUES??????) THAN
> GIVE ME A QUICK FIX. SO I APPEAL TO YOU ALL
> OVERSEAS HOPING THAT MOST OF YOU HAVE HYDE
> BURNERS AND HAVE SEEN (AND RECTIFIED THIS
> PROBLEM ) CHEERS

> PS GREAT SITE WISH I WAS OVER THERE
> MARTIN , MANCHESTER , U.K.


Messages In This Thread